Electric Submersible Pump Cable 5AWG with Capillary

Type: Insulated
Conductor Type: Stranded
Application: Overhead, Heating, Underground
Conductor Material: Aluminum
Sheath Material: PVC
Insulation Material: Rubber
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (14)

Basic Info.

Material Shape
Flat Wire
Range of Application
Refractory
Brand
Slp
Transport Package
Cable Reel
Specification
14.5x39.6 mm
Origin
China
HS Code
8544601200
Production Capacity
1200 Kilometer/Kilometers Per Year

Product Description

Product Description
High Quality ESP Power Polypropylene Insulation Aluminium Flat Cable

Product name

ESP Power Aluminium Cable

Number of cores

3

Nominal cross section(mm2/AWG)

25

The number of conductors

1mm

Nominal diameter of single wire

5.64mm

Flat cable overall dimensions 3kv

14.5x39.6 mm

Flat cable overall dimensions 6kv

15.3x42.0 mm

Temperature resistance

90ºC

Voltage resistance KV

3, 6

 

Products and Technical Parameters

QYEQ Submersible Power Cable   

  • Products Description

    EPDM insulation, Inner lead sheath,Fiber tape covered completely over the lead sheath, Nitrile rubber jacket, Full galvanized steel (or Stainless steel or Monel) tape armour, Round type.

  • Production Range

    Voltage: 3kV 4kV 5kV 6kV

    Temperature: The permissible and long-term working temperature is 120ºC(248ºF).

  • Performing Criterion

    GB/T16750-2008,API RP 11S6-2008

  • Application Range

    The cable is applicable for using in Electricity Submersible Pump Units with rated voltage less than 3kV or 6kV. It has the excellent ability of oil-resistance, heat-resistance and corrosion-resistance.

  • Delivery & Packing

    We use all steel corrugated reels with rapped fuming wood outside, the packing length is according to customers' requirements, general minimum length is 1000 meters(3281 Feet); the cable are not allowed to knock against or twist, both ends should be moistureproof.

  • Cable's Cross Section Chart

     

Index of Performance

 

Cross

Section

Conductor

Diameter

mm

3kV

Insulation

Resistance

MΩ·km

3kV

Leakage Current

 at 15.6ºC

μA/km/kV

6kV

Insulation Resistance

MΩ·km

6kV

Leakage Current

μA/km/kV

DC Voltage Test

For 5 Minutes

mm2

AWG

3kV

6kV

33.5

2

6.54

1012

0.984

1170

0.853

27kV

35kV

42.5

1

7.35

919

1.083

1063

0.951

27kV

35kV



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2019

Suppliers with verified business licenses

Trading Company
Number of Employees
7
Year of Establishment
2018-11-09